Pro-E to IGES Translation

Use the GEOMCHECKS command to check the number of patched surfaces. This number should equal zero. Fix all patched surfaces when possible.

After creating the IGES file in Pro-E, try reading the file back into Pro-E. If the IGES file has any errors chances are that they will also cause errors in our translation software.

Use the following settings for Pro-E IGES output configuration for importing to SolidWorks:

Iges_out_all_srfs_as_128

Iges_out_spl_crvs_as_126 YES

Iges_out_spl_srfs_as_128 YES

Iges_out_trim_xyz NO

Iges_out_mil_d_28000 NO

Iges_out_trim_srfs_as_143 NO

Iges_out_JAMAIS_compliant NO

Iges_out_trim_curve_deviation DEFAULT

Intf_out_blanked_entities YES

Intf3d_out_extend_surface NO

 
 
 
 
 
 
 